Sale!

Factory outlet Q switch nd yag laser tattoo removal & skin whitening machine

$1,100.00 $950.00

Description


Introduction:

ND: YAG Cosmetic System introduces gem-adjusting Qswitch, which uses high energy by instant emission of beam to crush and removethe pigment effectively in the pathologically changed tissues. That is anexplosion led by beam: the beam at the fixed wavelength enabled by theaccumulated high energy can reach the pathologically changed tissues through epidermis in a very short time (only 6 ns) to instantly crush the respectivecolor base, then the corresponding pigment group gets swollen and outburst atlast due to high energy, and part of the pigment group springs out of the humanbody (at shallow epidermis), and the rest (at basis tissues) pigment group willbecome very small particle before swallowed by the human cell which will befinally discharged out of the human body through lymphatic system circulation. The pigment of the pathological tissues will fade in color till it vanishes.And the surrounding normal tissues will not be ruined since they will notabsorb the at that fixed wavelength.

Application:

The system gem-adjusting Q switch can effectively cure the mixed pigments bypigment precipitation of extraneous source with pathological pigment change ofendogenous source, inclusive of erroneous dark eyebrow-embroidery,lip-embroidery, lip-soak, eye line-embroidery, lip-line, tattoo (inclusive oftattoo by extraneous wounds), pigment precipitation by sensitive source,freckle on female’s face (male’s), coffee spot, old age spot, black mole, andbirthmark in black, blue, purple, brown,red and etc. Operation course fordifferent illness case as follows:

Treatments Treatment course required Treatment course interval Remark (requirements in surgery)
Birthmark,nevus/mole 3-7 times 45-90 days Blood infiltration is effective
Freckle, age spot 1-4 times 15-30 days Blood infiltration is fine on wounds
Tattoos 1-4 times 30-60 days Blood infiltration is fine on wounds
Lip line (red dyed lip) 1-3 times 15-45 days By 532nm filter
Eyebrow-embroidery 1-3 times 45-60 days Eyebrow blow, eyeball protection
eyebrow-embroidery 1 –2 times 30-60 days Eyebrow blow, eyeball protection

1)Treatmentfor tattoo in eyebrow
Customer could not open eyes during the treatment.The operator should adjust energy according to depth of tattoo color, hold the handle and move it to treatmentarea slowly to make the customer feel acceptable in mentally. Right now, the speed of flash couldbe set 3HZ, keep head of the handle a two-finger distance totreatment area, start treatment from head of eyebrow to end of eyebrow.
It isneeded to treat again in 5-10 minutes if the color of tattoo re-appear.

2)Eye line removal
The speed of flashes could be set 4-5HZ,adjust the energy of light to minimum energy, keep a one-finger distance between the head of handle and the treatment area.The operator should strictly protect customers` eyes with panel for eyelid ormedical pledget (panel for eyelid)of 25px depth. Treatment should be started from down eye line.The customer should deeply close eyes and keep eyeball up-sight inside. The operator should press the pledget (panelfor eyelid) with forefinger and push up eyelid,peel down eyelid with middlefinger to bare the eye line, treat it with flashes of 4-5Hz. Then, treat up eyeline. Also customer should close eyes and keep eyeball down-sight inside.The operator should press the pledget (panel for eyelid) with middle finger andpush eyelid down, push eyelid up with forefinger to bare the eye line, treat itwith flashes of 4-5Hz.

3)Lip line removal
The speed of flashes could be set 5Hz,keep a 3/4 finger distance between head of handle and treatment area. It is better to remove black, coffee, deep, redand brown lip line with 1064nm head at first time and then, treat again with 532 nm head.
Notice: All tattoos in lip should be treated in 6 months after making, or tattoo removal treatment will fail. It should have 45-60 days interval to continuenext treatment until remove all.

4)Tattoo removal
The speed of flashes could be set 3Hz/5Hz.It is better to use high energy fortreatment until treatment area seeps a little blood. It should have 45-90 days interval to continue next treatment until all tattoos are removed.

5)Spot and nevus removal
The speed of flashes could be set 3Hz/5Hz.Keep 3-4 fingers distance between the head of handle and the treatment area. It is better to use high energy for treatment until treatment area seeps a little blood. It is advised to use 1064nm head for normal spot and nevus treatment, but for deep color spot and nevus,it is better to use 532nm head for treatment. It should have a 15-30 days interval to continue next treatment until remove all.

6)Birthmark removal
The speed of flashes could be set 3Hz/5Hz.It is better to use high energy fortreatment until treatment area seeps a little blood. It is advised to use 1064nm head for birthmark treatment, but for red and deep color birthmark, it is better to use 532nm head for treatment. It should have 45-90 days intervalto continue.

 Advantages:
1.Faster tatoo removal:The output energy can reach 2000mj, which appears faster and better treatment effect.
2.Longer lifetime & longer working:with special temperature control system,the machine can keep working for longer time and the lifetime is longer than most ones in the market.
3.All key parts,like power supplies, the mainboard, the capacitance and the controller,are the best ones inported from Germany and USA,which ensures tattoo removal machine`s long time using-lift. And it assures our tattoo removal machine behavior more stabilized and the works be more reliable.

4.Aiming light: net imports of infrared indicator to spot more accurate treatment has greatly enhanced point utilization, besides,it also ensures the accuracy of long treatment and easy for the operator to handle.
5.We offer original lamps parts of our tattoo removal machine which are made by the best Chinese optical manufacturers 11th Institute, the best organization to provide the lamps. You can change the lamps by yourself, pretty easy to operate. Our lamps can operate for 100~120 thousand shots.
6.The Plug head stainless steel, quite durable.532nm head is used for the treatment of the brown and red pigment. 1064nm head can be used for the treatment of the black and the blue pigment.

Machine photos:





Specifications:
Light source ——————-Q-switched Nd: YAG solid-state laser
Wavelength——————-1064nm/532nm/1320nm
Energy level———————2000mj
Fluence ———————–≤ 20mJ/cm2
Pulse duration —————–8ns
Frequency———————–1-10Hz
Cooling system—————Built-in distilled water-circle system
Power requirement———-Single-phase 220V/10A
Size of the machine———-49×25×24cm
Weight—————————16kg

Reviews

There are no reviews yet.

Be the first to review “Factory outlet Q switch nd yag laser tattoo removal & skin whitening machine”

Your email address will not be published. Required fields are marked *

X